|
|
Logo |
Type |
Model # |
Host-to-Disk
channel |
HDD bay |
|

FastStream-VT5700


datasheet

|
-
Configurable for 1 or
2
Virtual Tape Libraries
-
Up to 30 Virtual Tape
drives and 256 Virtual Tapes per Library
-
RAID Levels 0, 1, 5, 10
-
Dual 4Gb Fibre Channel
Host Interfaces
-
Dual 4Gb Fibre Channel
Device Interfaces
-
One-click installation to
simplify configuration and management
-
Drive Initialization and
Verification feature identifies drives with soft errors or
performance issues
-
SpeedWrite Feature boosts
write performance by efficiently managing writes between the
server and virtual tape drives
-
1.89TB/hour ... 525MB/sec
-
HDD is significantly more
reliable, with no cleaning or streaming problems
-
Compatible with all
industry-leading backup software
-
ExpressNAV™ browser-based
management console for remote configuration, management, and
diagnostic capabilities
-
On-the-fly tape expansion
allows the user to increase the amount of virtual tapes
available without having to purchase additional virtual tape
hardware
-
OS independent enables
easy integration into current infrastructure
-
Phone home error
notification
-
RoHS Compliant
|
|

FastStream-VT5300


datasheet

|
-
Configurable for 1 or
2
Virtual Tape Libraries
-
Up to 30 Virtual Tape
drives and 256 Virtual Tapes per Library
-
RAID Levels 0, 1, 5, 10
-
Dual 4Gb Fibre Channel
Host Interfaces
-
Dual Ultra320 SCSI Device
Interfaces
-
One-click installation to
simplify configuration and management
-
Global Hot Spares allow
faulted drives to automatically rebuild
-
SpeedWrite Feature boosts
write performance by efficiently managing writes between the
server and virtual tape drives
-
1.89TB/hour ... 525MB/sec
-
HDD is significantly more
reliable, with no cleaning or streaming problems
-
Compatible with all
industry-leading backup software
-
ExpressNAV™ browser-based
management console for remote configuration, management, and
diagnostic capabilities
-
On-the-fly tape expansion
allows the user to increase the amount of virtual tapes
available without having to purchase additional virtual tape
hardware
-
OS independent enables
easy integration into current infrastructure
-
Phone home error
notification
-
RoHS Compliant
|
|

FastStream-SC7500


datasheet

|
-
Four 4Gb Fibre
Channel Host Interfaces
-
Eight 3Gb SAS/SATA Device
port via two four-port MiniSAS
-
RAID level - DVRAID, 0, 1,
4, 5, 10, 40, 50 (Power Center required for 40, 50)
-
Up to 1200MB/sec
performance in RAID 5
-
Real-time performance
metrics
-
Drive Initialization
and Verification feature identifies drives with soft errors
or performance issues
-
ExpressNAV™
integrated management console for remote configuration,
management and diagnostic capabilities
-
Aggregate storage for
best performance, create a large pool of storage
-
Add storage as needed
with minimal or no downtime
-
OS independent
enables easy integration into current infrastructure
-
Phone home error
notification
-
RoHS Compliant
|
|

FastStream-SC7700


datasheet

|
-
Two 4Gb Fibre
Channel Host Interfaces
-
Two 4Gb Fibre Channel Device
Interfaces
-
RAID level - DVRAID, 0, 1,
4, 5, 10, 40, 50 (Power Center required for 40, 50)
-
Up to 750MB/sec
performance in RAID 5
-
Real-time performance
metrics
-
Drive Initialization
and Verification feature identifies drives with soft errors
or performance issues
-
ExpressNAV™
integrated management console for remote configuration,
management and diagnostic capabilities
-
Aggregate storage for
best performance, create a large pool of storage
-
Add storage as needed
with minimal or no downtime
-
OS independent
enables easy integration into current infrastructure
-
Phone home error
notification
-
RoHS Compliant
|
|

FastStream-SC5700


datasheet

|
-
Add instant data
protection - DVRAID and RAID Levels 0, 1, 5, 10
-
Add SAN Functionality
to existing SCSI Storage
-
Dual 4Gb Fibre
Channel Host Interfaces
-
Dual 4Gb Fibre
Channel Device Interfaces
-
Drive Partitioning
allows you to create smaller partitions on large RAID
drives.
-
Global Hot Spares
allow faulted drives to automatically rebuild
-
Drive Initialization
and Verification feature identifies drives with soft errors
or performance issues
-
Increase system
performance to match application needs , up to 480MB/s
performance
-
ExpressNAV™
integrated management console for remote configuration,
management and diagnostic capabilities
-
Storage pooling
improves utilization of existing storage while reducing
managerial and administrative overhead
-
Add storage as needed
with minimal or no downtime
-
OS independent
enables easy integration into current infrastructure
-
Phone home error
notification
-
RoHS Compliant
|
|

FastStream-SC5300


datasheet

|
-
Add instant data
protection - DVRAID and RAID Levels 0, 1, 5, 10
-
Add SAN Functionality
to existing SCSI Storage
-
Dual 4Gb Fibre
Channel Host Interfaces
-
Dual Ultra320 SCSI
Device Interfaces
-
Drive Partitioning
allows you to create smaller partitions on large RAID
drives.
-
Global Hot Spares
allow faulted drives to automatically rebuild
-
Drive Initialization
and Verification feature identifies drives with soft errors
or performance issues
-
Increase system
performance to match application needs
-
ExpressNAV™
integrated management console for remote configuration,
management and diagnostic capabilities
-
Storage pooling
improves utilization of existing storage while reducing
managerial and administrative overhead
-
Add storage as needed
with minimal or no downtime
-
OS independent
enables easy integration into current infrastructure
-
Phone home error
notification
-
Supports SCSI and
Fibre Channel (future) storage devices
-
(Future) support for
SAS/SATA and Fibre Channel
-
RoHS Compliant
|
|
FS-4500
datasheet
|
-
RAID level 0, 1, 3, 5,
10, 30, 50, JBOD using Multiple XOR techniques
-
Host independent, no
driver required to the host bus
-
Host interface:
Dual
Loop
2Gb Fibre Channel,
bandwidth up to
400MB/sec
-
12 x SATA 3.0 Gb HDD bay,
with dual port access and failover to each HDD
-
Dual redundant power
supply, hot swap capable
-
256MB ECC cache, up to
1GB to each controller
-
Dynamic online RAID
expansion, partitioning, and reconfiguration
-
10/100 Ethernet port, and
RS232 port for monitoring and configuration
-
up to
48,000 IOPS and 385MByte/sec
(sustained reads)
-
Dual Active redundant
failover/failback RAID controller
-
Battery protected
mirrored write cache
-
SAN
ready, Full Fabric support

|
|

SOL SAS16e-F4

datasheet


|
-
64-bit RISC CPU (800Mhz)
-
Standard 256MB ECC cache for each controller, Up to 4GB with
resizing
-
Hot Swappable /
Dual Redundant Controllers or Single
Controller
-
RAID 0, 1, 3, 5, 6, 10, 30, 50, 60, JBOD
-
Active-Active Logical
Unit Access and Software Cache Mirroring
-
Hot Swap HDD, Auto-rebuilding, & Hot Spare
-
Fully modularized design
for highest reliability and easy maintenance
-
Remote GUI Management via
web browser
-
Host : Up to 4 x 4Gb Fibre Channel,32 Concurrent Hosts Supported
-
HDD : 16 x Dual Port SAS (3Gbs) interface also supporting SATA II (3Gbs)
-
Support Online Daisy
Chaining JBOD, up to 114 HDD are supported
-
Online RAID Expansion and
RAID level Migration
-
AC-DC/DC-DC six pairs of
redundant and load balance circuit design to reduce the HD bad
sector
-
Up to 256 LUNs is
Supported
-
Single Web Browser
Management Console to manage multiple RAID
-
Web Based Management
Interface, SNMP, Email Alert are supported
-
OS Support: Windows
Server 2003 / 2008, Windows 2000/NT/XP-Pro, Linux, Sun Solaris,
Tru64 Unix, HP-UX, IBM AIX, SGI Irix, Mac OS X, Free BSD

|
|

SOL SA16e-F4


|
-
Intel XScale 321 400 Mhz 64-bit RISC CPU
-
Standard 128MB cache RAM , Up to 1GB ECC supported
-
RAID 0, 1, 3, 5, 6, 10, JBOD
-
Hot Swap HDD, Auto-rebuilding, & Hot Spare
-
Fully modularized design
for highest reliability and easy maintenance
-
Remote GUI Management via
web browser
-
Host : 2 x 4Gb Fibre Channel,400MB/sec per channel
-
HDD : 16 x SATA II (3Gbs) HDD interface
-
RAID disk Roaming between
RAID subsystems
-
Background Initialization
for fast use
-
Online RAID level
Migration and Volume Expansion
-
Allow HDD capacity
truncation after decimal point for RAID creation
-
S.M.A.R.T. features
embedded with all disk from any manufactures for bad sector and
disk error handling
-
Smart LCD display with
buttons to configure and monitoring

|
|

SOL SA12e-F4


|
-
Intel XScale 321 400 Mhz 64-bit RISC CPU
-
Standard 128MB cache RAM , Up to 1GB ECC supported
-
RAID 0, 1, 3, 5, 6, 10, JBOD
-
Hot Swap HDD, Auto-rebuilding, & Hot Spare
-
Fully modularized design
for highest reliability and easy maintenance
-
Remote GUI Management via
web browser
-
Host : 2 x 4Gb Fibre Channel,400MB/sec per channel
-
HDD : 12 x SATA II (3Gbs) HDD interface
-
RAID disk Roaming between
RAID subsystems
-
Background Initialization
for fast use
-
Online RAID level
Migration and Volume Expansion
-
Allow HDD capacity
truncation after decimal point for RAID creation
-
S.M.A.R.T. features
embedded with all disk from any manufactures for bad sector and
disk error handling
-
Smart LCD display with
buttons to configure and monitoring

|
|

SOL SA8e-F4


|
-
Intel XScale 219 400 Mhz 64-bit RISC CPU
-
Standard 128MB cache RAM , Up to 1GB ECC supported
-
RAID 0, 1, 3, 5, 6, 10, JBOD
-
Hot Swap HDD, Auto-rebuilding, & Hot Spare
-
Fully modularized design
for highest reliability and easy maintenance
-
Remote GUI Management via
web browser
-
Host : 2 x 4Gb Fibre Channel,400MB/sec per channel
-
HDD : 8 x SATA II (3Gbs) HDD interface
-
RAID disk Roaming between
RAID subsystems
-
Background Initialization
for fast use
-
Online RAID level
Migration and Volume Expansion
-
Allow HDD capacity
truncation after decimal point for RAID creation
-
S.M.A.R.T. features
embedded with all disk from any manufactures for bad sector and
disk error handling
-
Smart LCD display with
buttons to configure and monitoring
-
The ONLY 8-bay Fibre
Channel RAID in the world ...

|
|

SOL iSA16

datasheet
|
-
Intel XScale 331 500 Mhz 64-bit RISC CPU
-
Standard 128MB cache RAM , Up to 2GB ECC supported
-
RAID 0, 1, 3, 5, 6, 0+1, 30, 50, 60, JBOD
-
Host : 2 x 1Gb Ethernet/iSCSI, 1Gb/sec per Channel
-
HDD : 16 x SATA II (3Gbs) HDD Interface
-
RAID Disk Roaming between
RAID Subsystems
-
Hot Swap HDD,
Auto-rebuilding, & Hot Spare
-
Remote GUI Management via
web browser
-
LCD panel with buttons
and CLI also provided for configuration and monitoring
-
Background Initialization
for fast use
-
Online RAID level
Migration and Volume Expansion
-
Allow HDD capacity
truncation after decimal point for RAID creation
-
250W x 3 Hot Swappable / Redundant Power Supply
-
Upgradeable to iSCSI + SCSI Host channel to iSCSI
SAN and Direct Attached

|
|

SOL SA16

|
-
Intel XScale 331 500 Mhz 64-bit RISC CPU
-
Standard 128MB cache RAM , Up to 2GB ECC supported
-
RAID 0, 1, 3, 5, 6, 0+1, 30, 50, 60, JBOD
-
Host : 2 x Ultra320 SCSI, 320MB/sec per Channel
-
HDD : 16 x SATA II (3Gbs) HDD Interface
-
RAID Disk Roaming between
RAID Subsystems
-
Hot Swap HDD,
Auto-rebuilding, & Hot Spare
-
Remote GUI Management via
web browser
-
LCD panel with buttons
and CLI also provided for configuration and monitoring
-
Background Initialization
for fast use
-
Online RAID level
Migration and Volume Expansion
-
Allow HDD capacity
truncation after decimal point for RAID creation
-
250W x 3 Hot Swappable / Redundant Power Supply
-
Upgradeable to iSCSI + SCSI Host channel to iSCSI
SAN and Direct Attached

|
|

SOL SA16e

|
-
Intel XScale 321 400 Mhz 64-bit RISC CPU
-
Standard 128MB cache RAM , Up to 1GB ECC supported
-
RAID 0, 1, 3, 5, 6, 10, JBOD
-
Hot Swap HDD, Auto-rebuilding, & Hot Spare
-
Fully modularized design
for highest reliability and easy maintenance
-
Remote GUI Management via
web browser
-
Host : 2 x U320 SCSI,320MB/sec per channel
-
HDD : 16 x SATA II (3Gbs) HDD interface
-
RAID disk Roaming between
RAID subsystems
-
Background Initialization
for fast use
-
Online RAID level
Migration and Volume Expansion
-
Allow HDD capacity
truncation after decimal point for RAID creation
-
S.M.A.R.T. features
embedded with all disk from any manufactures for bad sector and
disk error handling
-
Smart LCD display with
buttons to configure and monitoring

|
|

SOL SA12e

|
-
Intel XScale 321 400 Mhz 64-bit RISC CPU
-
Standard 128MB cache RAM , Up to 1GB ECC supported
-
RAID 0, 1, 3, 5, 6, 10, JBOD
-
Hot Swap HDD, Auto-rebuilding, & Hot Spare
-
Fully modularized design
for highest reliability and easy maintenance
-
Remote GUI Management via
web browser
-
Host : 2 x Ultra320 SCSI,320MB/sec per channel
-
HDD : 12 x SATA II (3Gbs) HDD interface
-
RAID disk Roaming between
RAID subsystems
-
Background Initialization
for fast use
-
Online RAID level
Migration and Volume Expansion
-
Allow HDD capacity
truncation after decimal point for RAID creation
-
S.M.A.R.T. features
embedded with all disk from any manufactures for bad sector and
disk error handling
-
Smart LCD display with
buttons to configure and monitoring

|
|

SOL SA8e

|
-
Intel XScale 219 400 Mhz 64-bit RISC CPU
-
Standard 128MB cache RAM , Up to 1GB ECC supported
-
RAID 0, 1, 3, 5, 6, 10, JBOD
-
Hot Swap HDD, Auto-rebuilding, & Hot Spare
-
Fully modularized design
for highest reliability and easy maintenance
-
Remote GUI Management via
web browser
-
Host : 2 x 4Gb Fibre Channel,400MB/sec per channel
-
HDD : 8 x SATA II (3Gbs) HDD interface
-
RAID disk Roaming between
RAID subsystems
-
Background Initialization
for fast use
-
Online RAID level
Migration and Volume Expansion
-
Allow HDD capacity
truncation after decimal point for RAID creation
-
S.M.A.R.T. features
embedded with all disk from any manufactures for bad sector and
disk error handling
-
Smart LCD display with
buttons to configure and monitoring

|
|

SOL SA8-v

datasheet
|
-
Intel XScale 331 500 Mhz 64-bit RISC CPU
-
Standard 128MB cache RAM , Up to 2GB ECC supported
-
RAID 0, 1, 3, 5, 6, 0+1, 30, 50, 60, JBOD
-
Host : 2 x Ultra320 SCSI, 320MB/sec per Channel
-
HDD : 8 x SATA II (3Gbs) HDD Interface
-
RAID Disk Roaming between
RAID Subsystems
-
Hot Swap HDD,
Auto-rebuilding, & Hot Spare
-
Remote GUI Management via
web browser
-
LCD panel with buttons
and CLI also provided for configuration and monitoring
-
Background Initialization
for fast use
-
Online RAID level
Migration and Volume Expansion
-
Allow HDD capacity
truncation after decimal point for RAID creation
-
300W x 2 Hot Swappable / Redundant Power Supply

|
|

SOL i8

datasheet
|
-
Intel XScale 321 400 Mhz 64-bit RISC CPU
-
Standard 128MB cache RAM , Up to 1GB ECC supported
-
RAID 0, 1, 3, 5, 6, 10, JBOD
-
Hot Swap HDD, Auto-rebuilding, & Hot Spare
-
Fully modularized design
for highest reliability and easy maintenance
-
Remote GUI Management via
web browser
-
Host : 2 x Ultra160 SCSI,160MB/sec per channel
-
HDD : 8 x EIDE HDD interface
-
RAID disk Roaming between
RAID subsystems
-
Background Initialization
for fast use
-
Online RAID level
Migration and Volume Expansion
-
Allow HDD capacity
truncation after decimal point for RAID creation
-
S.M.A.R.T. features
embedded with all disk from any manufactures for bad sector and
disk error handling
-
Smart LCD display with
buttons to configure and monitoring

|
|

SOL SA5 (U320 SCSI)
SOL SA5-FW
(Combo)

datasheet
|
-
Intel 80219 400 Mhz
64-bit RISC CPU
-
Standard 128MB cache RAM
-
RAID 0, 1, 3, 5, 6, 10, JBOD
-
Hot Swap HDD, Auto-rebuilding, & Hot Spare
-
Host : 1 x Ultra320 SCSI,320MB/sec per channel (SA5-U320)
Host : 1 x USB 2.0 + 1 x 1394b FireWire (SA5-FW)
-
HDD : 5 x SATA II (3Gb/s) HDD interface
-
Background Initialization
for fast use
-
Online RAID level
Migration and Volume Expansion
-
Smart LCD display with
buttons to configure and monitoring
-
Web Browser Management
Utility Embedded
|
SA5-U320 |
SA5-FW |
|
Ultra 320 SCSI |
USB 2.0 + 1394b |
|
320 MByte/sec |
60 MByte/sec
480 Mb/sec |
100 MByte/sec
800 Mb/sec |

|
|

SOL SA16-is

|
-
2 x CPU !! , Intel 64-bit RISC CPU
- RAID : Intel XScale 331 500 Mhz
- iSCSI 550 : 80321 600Mhz <- High Performance
-
Standard 128MB cache RAM , Up to 2GB ECC supported
- Secondary Cache 128MB dedicated for
iSCSI and TOE processing
-
RAID 0, 1, 3, 5, 6, 0+1, 30, 50, 60, JBOD
-
Host : Two different host channels
working simultaneously
- 1 x 1Gb iSCSI , 1Gb/s
- 1 x Ultra320 SCSI,320MB/sec
-
iSCSI
device Expansion - Daisy Chainable HDD, RAID, Tape Library,
Jukebox of DVD/CD, ... then become iSCSI devices for SAN users
-
HDD : 16 x SATA II (3Gbs) HDD Interface
-
RAID Disk Roaming between
RAID Subsystems
-
Hot Swap HDD,
Auto-rebuilding, & Hot Spare
-
Remote GUI Management via
web browser
-
LCD panel with buttons
and CLI also provided for configuration and monitoring
-
Background Initialization
for fast use
-
Online RAID level
Migration and Volume Expansion
-
Allow HDD capacity
truncation after decimal point for RAID creation
-
250W x 3 Hot Swappable / Redundant Power Supply
-
Upgradeable to iSCSI + SCSI Host channel to iSCSI
SAN and Direct Attached

|
|

SOL SA8-is

|
-
2 x CPU !! , Intel 64-bit RISC CPU
- RAID : Intel XScale 331 500 Mhz
- iSCSI 550 : 80321 600Mhz <- High Performance
-
Standard 128MB cache RAM , Up to 2GB ECC supported
- Secondary Cache 128MB dedicated for
iSCSI and TOE processing
-
RAID 0, 1, 3, 5, 6, 0+1, 30, 50, 60, JBOD
-
Host : Two different host channels
working simultaneously
- 1 x 1Gb iSCSI , 1Gb/s
- 1 x Ultra320 SCSI,320MB/sec
-
iSCSI
device Expansion - Daisy Chainable HDD, RAID, Tape Library,
Jukebox of DVD/CD, ... then become iSCSI devices for SAN users
-
HDD : 8 x SATA II (3Gbs) HDD Interface
-
RAID Disk Roaming between
RAID Subsystems
-
Hot Swap HDD,
Auto-rebuilding, & Hot Spare
-
Remote GUI Management via
web browser
-
LCD panel with buttons
and CLI also provided for configuration and monitoring
-
Background Initialization
for fast use
-
Online RAID level
Migration and Volume Expansion
-
Allow HDD capacity
truncation after decimal point for RAID creation
-
300W x 2 Hot Swappable / Redundant Power Supply
-
Upgradeable to iSCSI + SCSI Host channel to iSCSI
SAN and Direct Attached

|
|

SOL i8-is

datasheet
|
-
2 x CPU !! , Intel XScale 64-bit RISC
- RAID : Intel XScale 321 400 Mhz 64-bit RISC CPU
- iSCSI : 80321 600Mhz <-- High Performance
-
Standard 128MB cache RAM , Up to 1GB ECC supported
- Secondary Cache 128MB dedicated for
iSCSI and TOE processing
-
RAID 0, 1, 3, 5, 6, 10, JBOD
-
Hot Swap HDD, Auto-rebuilding, & Hot Spare
-
Fully modularized design
for highest reliability and easy maintenance
-
Remote GUI Management via
web browser
-
Host : Two different host channels
working simultaneously
- 1 x 1Gb iSCSI , 1Gb/s
- 1 x Ultra160 SCSI,160MB/sec
-
iSCSI
device Expansion - Daisy Chainable HDD, RAID, Tape Library,
Jukebox of DVD/CD, ... then become iSCSI devices for SAN users
-
HDD : 8 x EIDE HDD interface
-
RAID disk Roaming between
RAID subsystems
-
Background Initialization
for fast use
-
Online RAID level
Migration and Volume Expansion
-
Allow HDD capacity
truncation after decimal point for RAID creation
-
S.M.A.R.T. features
embedded with all disk from any manufactures for bad sector and
disk error handling
-
Smart LCD display with
buttons to configure and monitoring

|
Specifications subject to change without
notice.
Contact us for more information.
|